Capillary Arrays

We have developed specialized capillary arrays for use with our instruments – enabling superior separation resolution and nucleic acid quantification.

Reagent Kit Box

Capillary Arrays

FA 12-Capillary Array Ultra-Short (A2300-1250-2247): 22 cm effective length, 47 cm overall length; 12 parallel capillaries. The shortest length array for the Fragment Analyzer, designed for faster separations without sacrificing separation quality.

FA 12-Capillary Array Short (A2300-1250-3355): 33 cm effective length, 55 cm overall length; 12 parallel capillaries. The standard length array for the Fragment Analyzer, it is compatible with all gel kits. With 12 parallel capillaries this array is ideal for lower throughput environments or laboratories that prefer to separate samples or users by row.

FA 12-Capillary Array Long (A2300-1250-5580): 55 cm effective length, 80 cm overall length; 12 parallel capillaries. Enables enhanced separation resolution. Perfect for low throughput settings or laboratories that prefer to separate samples or users by row that demand enhanced separation resolution.

FA 48-Capillary Array Short (A2300-4850-3355): 33 cm effective length, 55 cm overall length; 48 parallel capillaries. The standard length array for the Fragment Analyzer configured to simultaneously separate 48 samples in parallel it is ideal for medium to high-throughput environments.

FA/ZAG 96-Capillary Array Short (A2300-9650-3355): 33 cm effective length. 55 cm overall length; 96 parallel capillaries. The standard length capillary array for the Fragment Analyzer, it is ideal for high-throughput environments with the capability to separate 96 samples in parallel.

FA/ZAG 96-Capillary Array Long (A2300-9650-5580): 55 cm effective length, 80 cm overall length; 96 parallel capillaries. Provides enhanced separation resolution to high throughput environments. Separate 96 samples in parallel.

To select the capillary array that best fits your needs use the tables below. The top table provides information for the quantitative gel kits while the bottom table provides information for the qualitative gel kits.

Separation times are reported in minutes.
Quantitative Analysis
NGS LF Genomic RNA
DNF-473 DNF-474 DNF-477 DNF-464 DNF-492 DNF-493 DNF-467 DNF-468 DNF-487 DNF-488 DNF-470 DNF-471 DNF-472
FA 12-Capillary Array Ultra-Short 25 30 35 50 50 30 30 17 31 31
FA 12-Capillary Array Short 50 50 40 55 50 50 60 60 50 50 22 40 40
FA 12-Capillary Array Long 80 80 80 80 80 80 70 70
FA 48-Capillary Array Short 50 50 40 55 50 50 60 60 50 50 22 40 40
FA/ZAG 96-Capillary Array Short 50 50 40 55 50 50 60 60 50 50 22 40 40
FA/ZAG 96-Capillary Array Long 80 80 80 80 80 80 70 70
Separation times are reported in minutes.
Qualitative CRISPR
DNF-900 DNF-905 DNF-910 DNF-915 DNF-920 DNF-930 DNF-935 DNF-910CP
FA 12-Capillary Array Ultra-Short 28 28 22 24 27 18 15 35
FA 12-Capillary Array Short 60 60 45 50 50 30 20 50
FA 12-Capillary Array Long 80 80 70 80 80 75 35
FA 48-Capillary Array Short 60 60 45 50 50 30 20 50
FA/ZAG 96-Capillary Array Short 60 60 45 50 50 30 20 50
FA/ZAG 96-Capillary Array Long 80 80 70 80 80 75 80
Top