Capillary Arrays

12 Capillary Ultra-Short Array (A2300-1250-2247): 22 cm effective length, 47 cm overall length; 12 parallel capillaries. The shortest length array for the Fragment Analyzer, designed for faster separations without sacrificing separation quality.

12 Capillary Short Array (A2300-1250-3355): 33 cm effective length, 55 cm overall length; 12 parallel capillaries. The standard length array for the Fragment Analyzer, it is compatible with all gel kits. With 12 parallel capillaries this array is ideal for lower throughput environments or laboratories that prefer to separate samples or users by row.

12 Capillary Long Array (A2300-1250-5580): 55 cm effective length, 80 cm overall length; 12 parallel capillaries. Enables enhanced separation resolution. Perfect for low throughput settings or laboratories that prefer to separate samples or users by row that demand enhanced separation resolution.

48 Capillary Short Array (A2300-4850-3355): 33 cm effective length, 55 cm overall length; 48 parallel capillaries. The standard length array for the Fragment Analyzer configured to simultaneously separate 48 samples in parallel it is ideal for medium to high-throughput environments.

96 Capillary Short Array (A2300-9650-3355): 33 cm effective length. 55 cm overall length; 96 parallel capillaries. The standard length capillary array for the Fragment Analyzer, it is ideal for high-throughput environments with the capability to separate 96 samples in parallel.

96 Capillary Long Array (A2300-9650-5580): 55 cm effective length, 80 cm overall length; 96 parallel capillaries. Provides enhanced separation resolution to high throughput environments. Separate 96 samples in parallel.

To select the capillary array that best fits your needs use the tables below. The top table provides information for the quantitative gel kits while the bottom table provides information for the qualitative gel kits.

Separation times are reported in minutes.
Quantitative Analysis
NGS LF Genomic RNA
DNF-473 DNF-474 DNF-477 DNF-464 DNF-492 DNF-493 DNF-467 DNF-487 DNF-488 DNF-470 DNF-471 DNF-472
12 Capillary Ultra-Short Array 25 30 35 30 30 17 31 31
12 Capillary Short Array 50 50 40 55 50 50 50 50 50 22 40 40
12 Capillary Long Array 80 80 80 80 80 80 70 70
48 Capillary Short Array 50 50 40 55 50 50 50 50 50 22 40 40
96 Capillary Short Array 50 50 40 55 50 50 50 50 50 22 40 40
96 Capillary Long Array 80 80 80 80 80 80 70 70
Separation times are reported in minutes.
Qualitative TILLiNG / CRISPR
DNF-900 DNF-905 DNF-910 DNF-915 DNF-920 DNF-930 DNF-935 DNF-910T DNF-920T DNF-910CP
12 Capillary Ultra-Short Array 28 28 22 24 27 18 15 35
12 Capillary Short Array 60 60 45 50 50 30 20 50 50 50
12 Capillary Long Array 80 80 70 80 80 75 35 80 80
48 Capillary Short Array 60 60 45 50 50 30 20 50 50 50
96 Capillary Short Array 60 60 45 50 50 30 20 50 50 50
96 Capillary Long Array 80 80 70 80 80 75 35 80 80